By Emmanuel Sauvage · Updated
Technical guide · standard
Bathroom zones: IP44, IP65 and NF C 15-100
In France, NF C 15-100 (part 7-701, bath or shower) defines zones where water and electricity come close. The IP rating of a fitting must match the zone where it is installed: it is not just a marketing label. This guide summarises zones 0, 1 and 2 with an IP table and a lux ↔ lumens ↔ watts converter by room type.
This page describes the French standard. In the UK, bathroom zones are set by BS 7671 (section 701), and in other countries by local wiring rules: check them, and have an electrician validate your installation.
The zones in brief
Simplified NF C 15-100 benchmarks (June 2015): zone 1 goes up to 2.25 m; zone 2 is a 0.60 m horizontal band around zone 1. Measure from the bath or shower tray and read the fitting’s instructions (IP44, IP65…). Have an electrician check if your layout is unusual.
Zones and IP table
| Zone | Boundary | Minimum IP | Voltage / equipment | Practical note |
|---|---|---|---|---|
| Zone 0 | Inside the bath or shower tray | IPX7 | SELV 12 V AC or 30 V DC max., source outside the zones | 230 V forbidden for lighting |
| Zone 1 | Above zone 0, up to 2.25 m | IPX4 (IPX5 for horizontal jets) | SELV 12 V only for light fittings | No 230 V |
| Zone 2 | 0.60 m band around zone 1 | IPX4 | Class II + 30 mA RCD, or SELV 12 V | Typical IP44 wall light above the mirror |
| Outside the zones | Rest of the room (former zone 3 removed in 2015) | No IP required by 7-701 | General household rules | IP44 is still a sensible choice near the basin |
IP44 = splashing water; IP65 = water jets, useful near a jet shower, outdoors or for a very exposed spotlight. Definitions: IP ratings guide. Mirror and colour: lighting the mirror, Kelvin, CRI.
Lux ↔ lumens ↔ watts converter
Choose a room type (area and comfortable lux) or change one of the three values: the other two are recalculated (K ≈ 2 for general lighting, LED ≈ 100 lm/W). Detailed method: lux per room.
≈ 175 lx × 6 m² × K 2 → 2,100 lm → ≈ 21 W LED
Changing lumens or watts recalculates the lux for the chosen area (K = 2). Changing lux or area recalculates lumens and watts.
Product ideas
Prices and availability change: check them before buying. As an Amazon Associate I earn from qualifying purchases.
Going further
Whole room: bathroom lighting. LED troubleshooting (glow, buzzing): LED troubleshooting guide. Bulb equivalence: lumens vs watts.
Have a question about this lighting or your wiring? Ask it here
Tell us the room, the bulb base or your electrical setup: we reply by email within 1 to 2 working days.