Error code guide

Shelly Dimmer 2 with no neutral at the ceiling light

The module does not start, its Wi-Fi LED stays off, or the bulb glows faintly after being switched off.

Error or symptom: No neutral / module will not start · Difficulty ●●●●○ (4/5) · Time 45–90 min · Cost €15–120 in France · Tools Shelly Bypass; an electrician if a neutral has to be run

Likely cause

A no-neutral installation without the Shelly Bypass, the capacitive load of LEDs, or a misidentified switched live.

Fix it step by step

  1. Check whether there is a neutral (blue) in the box. If not, fit the Shelly Bypass at the light, as shown in Shelly’s diagram.
  2. Follow Shelly’s official no-neutral wiring diagram exactly.
  3. Do not use non-dimmable bulbs with it.
  4. For two-way switching or any doubt, have an electrician run a neutral.
  5. If you are unsure which wire is which, stop and call a professional.

Safety: This is 230 V work at the ceiling rose. Without a neutral, the bypass must follow Shelly’s official diagram; a mistake can cause a shock or a fire.

These steps do not involve opening the product. If it is still under warranty, contact the manufacturer before any repair.

Official help: Shelly support.

← All error codes · Troubleshooting hub

Diagram: connected dimmer module offline
Shelly Dimmer 2 with no neutral at the ceiling light
At a glance
Difficulty●●○○○ (2/5)
Time15–30 min
Cost0 €

FAQ

What does “Shelly Dimmer 2 with no neutral at the ceiling light” mean on this model?

The module does not start, its Wi-Fi LED stays off, or the bulb glows faintly after being switched off.

Can I fix this without voiding warranty?

These steps do not involve opening the product. If unsure, contact the manufacturer before repairing.

Was this page helpful?

Have a question about this lighting or your wiring? Ask it here

Tell us the room, the bulb base or your setup (B22, E27, GU10): we reply by email within 1 to 2 working days.