1 — Main symptom

  • Flicker when on, especially at low dimmer setting → check dimmable marking, trailing vs leading edge, minimum load, replace incompatible dimmer.
  • Buzz from dimmer or lamp → halogen-era dimmer on LED, under-minimum load, mix of dimmable and non-dimmable — use LED-rated dimmer and matched bulbs.
  • Glow or flash when “off” → standby current through smart/no-neutral switch or dimmer leakage — bypass, compatible dimmable LED, or smart bulb with switch locked ON.
  • Flicker at 100 % on a simple switch → loose lamp, failing driver, or bad contact in GU10 holder — try another bulb, check lampholder.

Typical fixes (from our tree leaves)

CaseSchwierigkeitTimeCost
Non-dimmable LED on dimmer → swap for dimmable or remove dimmer15–15 min£5–25
Leading-edge dimmer + dimmable LED → trailing-edge LED dimmer2–320–45 min£25–55
Single low-power LED below dimmer minimum → add load or “low load” dimmer2–325–50 min£10–50
Smart switch without neutral + ghosting → manufacturer bypass at rose3–430–90 min£4–15 parts (+ electrician)

Matrix: dimmer × LED (FR). Smart bulbs: troubleshooting hub.

Cette page vous a-t-elle été utile ?

Haben Sie eine Frage zu dieser Beleuchtung oder Ihrer Installation? Schreiben Sie uns

Nennen Sie den Raum, den Sockel oder Ihre Elektroinstallation: Wir antworten per E-Mail innerhalb von 1 bis 2 Werktagen.